header-layer-bottom

A Battery Management System (BMS) has one primary job: to protect the lithium ion battery. When operating conditions are outside the safe operating limits (SOL), it can do that by disconnecting the battery.

That protects the battery, but it can create a different problem for the boat’s electrical system.

Consider what happens when a BMS disconnects while an alternator is running or a charger is delivering high current. The sudden loss of load can cause a sharp voltage spike, often referred to as a load dump. Without adequate protection, the resulting voltage transient can damage alternators, chargers, inverters, and other sensitive electronics connected to the DC bus.

This is why ABYC E-13, Lithium Ion Batteries, requires the boat’s electrical system to be designed to protect electrical components from damage in case the BMS disconnects a battery.

The question is how to achieve that protection in practice.


Coordinate the charging shutdown.

Where supported, use communication from the BMS to reduce or stop charging before the battery disconnects. Depending on the equipment, this may involve alternator field control, charger or MPPT shutdown signals.

Plan for an unexpected disconnect.

Not every BMS shutdown can be anticipated or coordinated. A fault can cause the battery to disconnect without warning, even when charging equipment is operating normally. Appropriately rated alternator protection devices, avalanche diodes, transient voltage suppressors (TVS), and other protection methods can help manage the resulting voltage spikes.

Maintain a battery connection.

One practical arrangement is to keep a lead acid battery connected to the alternator and charge the lithium ion battery bank through a DC-DC charger. This keeps a battery connected to the charging source even if the lithium BMS disconnects, reducing the risk of a damaging load dump.

Keep essential equipment powered.

A BMS shutdown should not necessarily mean losing navigation instruments or other critical systems. Providing an independent or alternative power source for essential loads can prevent a battery protection event from becoming a more serious problem.

The electrical system should be capable of handling a BMS disconnect under high charging loads without damaging connected equipment or causing a ‘dead ship condition’. ABYC E-13 Appendix 2 provides additional guidance on transient voltage risks and methods of reducing them.


The “Drop In Replacement” Myth

This brings us to one of the most misleading marketing claims in the marine lithium battery industry: the so called “drop in replacement.”

A lithium battery may fit in the same space and have the same nominal voltage as the lead acid battery it replaces. That doesn’t mean the existing electrical system is compatible with lithium ion technology.

Converting from lead acid to lithium is not simply a battery swap. It requires careful planning, equipment compatibility checks, and proper system design.


For more information refer to applicable ABYC Standards or contact ABYC Standards and Compliance Department at [email protected] for further information.

Contributed by Maciej Rynkiewicz, ABYC Standards Developer